Euclid VersaSpeed LS 100 is a single-component, rapid-strength repair mortar with about 45 minutes working time for horizontal and form-and-pour work. Light-duty traffic as soon as 4 hours; epoxy coats after 5 hours at 70 F. Low shrinkage.
Euclid VersaSpeed LS 100 is a single-component, rapid-hardening, shrinkage-compensated repair mortar that is micro-fiber reinforced, with extended working time for horizontal and form-and-pour work. It is used on bridges, highways and roads, parking decks and ramps, loading docks, warehouses, and industrial, commercial, and institutional floors, including formed vertical and overhead placements. The mortar is similar in appearance to concrete, freeze-thaw resistant, and carries an integral corrosion inhibitor.
| Property | Value |
|---|---|
| 3-hour compressive | 1,200 psi |
| 6-hour compressive | 2,800 psi |
| 28-day compressive | 8,000 psi |
| 28-day flexural | 820 psi |
| 28-day slant shear | 2,800 psi |
| Freeze/thaw, 300 cycles | >95% |
| Working time | 45 minutes |
| Initial set | 30 to 60 minutes |
| Application thickness | neat 1/4 to 4 in; extended 1 to 6 in |
| Yield | 0.39 ft³ per 50 lb |
VersaSpeed LS 100 Technical Data Sheet
How much working window does Euclid VersaSpeed LS 100 hold?
Working time is 45 minutes. Initial set is 30 to 60 minutes and final set is 60 to 100 minutes (ASTM C266). Typical laboratory values. Expect reasonable variation under field conditions.
What 6-hour cube strength does Euclid VersaSpeed LS 100 reach?
Typical laboratory value is 2,800 psi at 6 hours on 2 inch cubes (ASTM C109). 3-hour compressive strength is 1,200 psi; 28-day is 8,000 psi. Expect reasonable variation under field conditions.
When is Euclid VersaSpeed LS 100 open to standard tire traffic?
Standard tire traffic is 5 hours following final set. Light-duty traffic is as soon as 4 hours. Typical laboratory values. Expect reasonable variation under field conditions.
What epoxy-coat wait does Euclid VersaSpeed LS 100 need?
It can be coated with epoxy systems after 5 hours at 70 F. Typical laboratory value. Expect reasonable variation under field conditions.
What 28-day resistivity does Euclid VersaSpeed LS 100 show?
Surface resistivity is 31,300 ohm-cm at 28 days (FM 5-578). Typical laboratory value. Expect reasonable variation under field conditions.
What 300-cycle freeze-thaw result does Euclid VersaSpeed LS 100 show?
Freeze/thaw resistance is greater than 95% after 300 cycles (ASTM C666 Procedure A). Typical laboratory value. Expect reasonable variation under field conditions.
Please complete your information below to login.