Euclid UltraSil Li+ is a water-based lithium silicate densifier, sealer, and dustproofer in a 5 gallon pail. It is used on interior warehouse, retail, and diamond-polished floors.
Euclid UltraSil Li+ is a water-based lithium silicate densifier, sealer, and dustproofer. It is used on interior concrete floors, including warehouses, retail, diamond-polished floors, and clean rooms. It forms calcium silicate hydrate in the pores, so the treatment stays in the slab and does not peel. Air temperature should be between 35 F and 100 F.
| Property | Value |
|---|---|
| VOC | ≤ 5 g/L |
| Solids content | 15% |
| pH | 11.7 |
| Specific gravity | 1.10 |
| Foot traffic | 4 to 6 hours |
| Coverage | 250 to 800 ft²/gal |
| CDPH Standard Method v1.2, 2017 | listed |
| USGBC LEED Version 4, BD&C, ID&C | listed |
| The WELL Building Standard | listed |
| ANSI/GBI 01 | listed |
UltraSil Li+ Technical Data Sheet
Where is Euclid UltraSil Li+ used?
Interior concrete floors, including commercial and retail, warehouses, manufacturing plants, distribution centers, transportation terminals, institutional and health-care floors, clean rooms, and diamond-polished concrete.
What is the solids content of Euclid UltraSil Li+?
Typical laboratory solids content is 15%. pH is 11.7. Specific gravity is 1.10.
What is the coverage of Euclid UltraSil Li+?
Approximate coverage is 250 to 800 ft² per gallon depending on texture and porosity. Rates are for estimating only.
What is the CDPH listing of Euclid UltraSil Li+?
CDPH Standard Method v1.2, 2017. It also meets USGBC LEED Version 4 BD&C, ID&C, The WELL Building Standard, and ANSI/GBI 01.
How soon is Euclid UltraSil Li+ ready for foot traffic?
Typical laboratory foot traffic is 4 to 6 hours. Expect reasonable variation under field conditions.
What application temperature does Euclid UltraSil Li+ need?
Air temperature should be between 35 F and 100 F.
Please complete your information below to login.