Euclid Euco QWIKstitch is a two-component hybrid urethane repair liquid in a 2 gallon unit. Ultra-low viscosity so it penetrates cracks and repairs spalled joints, and it is mixed with kiln-dried sand as a mortar.
Euclid Euco QWIKstitch is a two-component hybrid urethane repair liquid. It is used to mend cracks in concrete, repair spalled floor joints, and repair pop-outs and delaminations. The ultra-low viscosity formula penetrates deep into cracks on interior and exterior slabs. There is no solvent odor, and placement is from 0 F to 110 F with a fast return to service.
| Property | Value |
|---|---|
| Mix ratio, Part A to Part B | 1:1 by volume |
| Sand to mixed liquid | 2:1 by volume |
| Gel time, 75 F | 2 to 3 minutes |
| Tack-free, 75 F | 10 minutes |
| Mortar thickness per lift | 1/2 in to 3 in |
| Mortar working time | < 3 minutes |
| Yield, 2 gallon | 462 in³ |
| Compressive strength, 1.5 hours, ASTM D695 | 4,610 psi |
| Bond strength, ASTM C882 | 1,880 psi |
| Application temperature | 0 F to 110 F |
EUCO QWIKstitch Technical Data Sheet
Where is Euclid Euco QWIKstitch used?
Euclid Euco QWIKstitch is used to mend cracks in concrete, repair spalled floor joints, and repair pop-outs and delaminations, interior or exterior.
What mortar thickness is Euclid Euco QWIKstitch placed at?
When mixed with kiln-dried sand, Euclid Euco QWIKstitch mortar is placed 1/2 in to 3 in per lift. Sand to mixed liquid is 2:1 by volume.
How soon must Euclid Euco QWIKstitch mortar be finished?
The 2 gallon mortar must be mixed, placed, and finished in less than 3 minutes. Typical laboratory gel time is 2 to 3 minutes at 75 F. Expect reasonable variation under field conditions.
What yield does Euclid Euco QWIKstitch have per 2 gallon unit?
Typical laboratory yield is 462 in³ per 2 gallon bulk unit. Expect reasonable variation under field conditions.
What 24-hour compressive strength does Euclid Euco QWIKstitch show?
Typical laboratory compressive strength is 4,610 psi at 1.5 hours and 5,050 psi at 24 hours (ASTM D695). Expect reasonable variation under field conditions.
What bond strength does Euclid Euco QWIKstitch show?
Typical laboratory bond strength is 1,880 psi (ASTM C882). Shore D hardness is 70 (ASTM D2240). Expect reasonable variation under field conditions.