Euclid QWIKjoint UVR is a UV-resistant, fast-setting semi-rigid polyurea joint filler in a 22 oz cartridge. It is used in construction and control joints on industrial and commercial floors, including freezer work.
Euclid QWIKjoint UVR is a UV-resistant, fast-setting semi-rigid polyurea joint filler. It is used in concrete construction and control joints, crack repair on older floors, and industrial and commercial slabs, including freezer floors. The formula is less moisture-sensitive and supports joint edges under heavy loads. Light traffic is typically ready in 1 hour and heavy traffic in 2 hours.
| Property | Value |
|---|---|
| Gel time | 25 to 30 seconds |
| Tack-free time | 3 to 4 minutes |
| Traffic ready | Light 1 hour; heavy 2 hours |
| Shore A, ASTM D2240 | 84 to 88 |
| Shore D, ASTM D2240 | 34 to 36 |
| Tensile strength, 7 days, ASTM D412 | 660 psi |
| Elongation, 7 days, ASTM D412 | 220% to 260% |
| Adhesion to concrete, 7 days, ASTM D4541 | 250 psi |
| Application temperature | -20 F to 90 F |
| Yield, 22 oz cartridge | 40 in³ |
EUCO QWIKjoint UVR Technical Data Sheet
Where is Euclid QWIKjoint UVR used?
Euclid QWIKjoint UVR is used in concrete construction and control joints, crack and joint repair on older floors, and industrial and commercial floors, including freezer floors. It supports and protects joint edges from heavy loads and wheel traffic.
What is the gel time of Euclid QWIKjoint UVR?
Typical laboratory gel time is 25 to 30 seconds. Tack-free time is 3 to 4 minutes. Expect reasonable variation under field conditions.
How soon is Euclid QWIKjoint UVR ready for traffic?
Typical laboratory traffic-ready time is 1 hour for light traffic and 2 hours for heavy traffic. Expect reasonable variation under field conditions.
What application temperature does Euclid QWIKjoint UVR need?
Euclid QWIKjoint UVR is placed from -20 F to 90 F. It cures in freezer floors as low as -20 F.
What is the adhesion of Euclid QWIKjoint UVR to concrete?
Typical laboratory adhesion to concrete is 250 psi at 7 days (ASTM D4541). Expect reasonable variation under field conditions.
What is the 7-day tensile strength of Euclid QWIKjoint UVR?
Typical laboratory tensile strength is 660 psi at 7 days (ASTM D412). Elongation at 7 days is 220% to 260%. Expect reasonable variation under field conditions.
Please complete your information below to login.