Euclid Euco QWIKstitch is a two-component hybrid urethane repair liquid in a 21.2 oz dual cartridge. Ultra-low viscosity so it penetrates cracks and repairs spalled joints and damaged concrete.
Euclid Euco QWIKstitch is a two-component hybrid urethane repair liquid. It is used to mend cracks in concrete, repair spalled floor joints, and repair pop-outs and delaminations. The ultra-low viscosity formula penetrates deep into cracks on interior and exterior slabs. There is no solvent odor, and placement is from 0 F to 110 F with a fast return to service.
| Property | Value |
|---|---|
| Gel time, 75 F | 2 to 3 minutes |
| Tack-free, 75 F | 10 minutes |
| Mixed viscosity | 60 cP |
| Shore D, ASTM D2240 | 70 |
| Tensile strength, 7 days, ASTM D638 | 3,410 psi |
| Compressive strength, 1.5 hours, ASTM D695 | 4,610 psi |
| Bond strength, ASTM C882 | 1,880 psi |
| Water absorption, ASTM D570 | 0.25% |
| VOC | 19 g/L |
| Application temperature | 0 F to 110 F |
EUCO QWIKstitch Technical Data Sheet
Where is Euclid Euco QWIKstitch used?
Euclid Euco QWIKstitch is used to mend cracks in concrete, repair spalled floor joints, and repair pop-outs and delaminations, interior or exterior.
What gel time does Euclid Euco QWIKstitch show at 75 F?
Typical laboratory gel time is 2 to 3 minutes at 75 F. Tack-free time is 10 minutes at 75 F. Expect reasonable variation under field conditions.
How soon is Euclid Euco QWIKstitch ready for heavy traffic?
Heavy traffic is typically ready in less than one hour. Typical laboratory compressive strength is 4,610 psi at 1.5 hours (ASTM D695). Expect reasonable variation under field conditions.
What mixed viscosity does Euclid Euco QWIKstitch show?
Typical laboratory mixed viscosity is 60 cP. Part A and Part B are each 60 cP. The ultra-low viscosity lets Euclid Euco QWIKstitch penetrate deep into cracks. Expect reasonable variation under field conditions.
What 1.5-hour compressive strength does Euclid Euco QWIKstitch show?
Typical laboratory compressive strength is 4,610 psi at 1.5 hours and 5,050 psi at 24 hours (ASTM D695). Expect reasonable variation under field conditions.
What application temperature does Euclid Euco QWIKstitch need?
Euclid Euco QWIKstitch is placed from 0 F to 110 F. Condition material to 60 F to 80 F before using.
Please complete your information below to login.