Eucorepair SCC is a versatile, one component, self-consolidating repair mortar that is shrinkage-compensated, polymer and microfiber modified, and contains an integral corrosion inhibitor. It is designed for horizontal and formed vertical/overhead structural repairs in applications from 1 inch (2.5 cm) to full depth.
Euclid EucoRepair SCC is a one-component, self-consolidating, shrinkage-compensated repair mortar that is polymer and microfiber modified and contains an integral corrosion inhibitor. It is used on parking decks, joint repairs, balconies, equipment bases, pavements, and beams, including formed vertical and overhead work. The mortar is freeze-thaw resistant, pre-mixed with pea gravel, and NSF/ANSI/CAN Standard 61 certified.
| Property | Value |
|---|---|
| 1-day compressive | 2,750 psi |
| 7-day compressive | 4,800 psi |
| 28-day compressive | 5,600 psi |
| 7-day flexural | 900 psi |
| Freeze/thaw, 300 cycles | >98% RDF |
| Chloride permeability, 28 days | <1,500 coulombs |
| Initial set | about 6 hours |
| Slump flow | 24 to 33 in |
| Application thickness | 1 in to full depth |
| Yield | 0.375 ft³ per 50 lb |
EucoRepair SCC Technical Data Sheet
When is Euclid EucoRepair SCC used on formed repairs?
Euclid EucoRepair SCC is used for horizontal and formed vertical and overhead structural repairs. Typical work includes parking decks, joint repairs, balconies, equipment bases, pavements, and beams.
What potable-water listing does Euclid EucoRepair SCC carry?
It is NSF/ANSI/CAN Standard 61 certified. That listing is on the current EucoRepair SCC data sheet.
When does Euclid EucoRepair SCC take initial set?
Initial set is approximately 6 hours (ASTM C403). Typical laboratory value. Expect reasonable variation under field conditions.
What 28-day cylinder strength does Euclid EucoRepair SCC reach?
Typical laboratory value is 5,600 psi at 28 days on 3 inch by 6 inch cylinders (ASTM C39). 7-day compressive strength is 4,800 psi; 1-day is 2,750 psi. Expect reasonable variation under field conditions.
What slump flow does Euclid EucoRepair SCC hold?
Slump flow is 24 to 33 inches initially and at 30 minutes (ASTM C1611). Typical laboratory value. Expect reasonable variation under field conditions.
What repair depth does Euclid EucoRepair SCC cover?
Application thickness is 1 inch to full depth. The mortar is designed for horizontal and formed vertical and overhead structural repairs in that range.