High performance hybrid anchoring and post-installed reinforcing bar system. The system is suitable for use in cracked and uncracked concrete in accordance with ACI 355.4 and ICC-ES AC308.
ULTRABOND HYB-2CC is a two-component hybrid anchoring adhesive with a 10:1 mix ratio for anchoring threaded rod and post-installed rebar in cracked or uncracked concrete. It is evaluated to ICC-ES AC308 and ACI 355.4 and is covered by ICC-ES ESR-4535. It installs in dry, water-saturated, and water-filled holes across a wide temperature range and is certified for potable water system components.
Mix Ratio | 10:1 by volume |
Consistency | Non-sag hybrid adhesive |
Installation Temperature Range | 23°F to 104°F |
Compressive Yield Strength (7 day) | Up to 15,049 psi (ASTM D695, Class C at 73°F) |
Bond Strength (Hardened Concrete, 14 day) | Up to 3,270 psi (ASTM C882) |
Heat Deflection Temperature | 258°F (ASTM D648) |
Water Absorption (14 day) | 0.90% (ASTM D570) |
Approvals and Listings | ICC-ES ESR-4535; IBC and IRC; City of Los Angeles; Florida Building Code; AASHTO M235 / ASTM C881 Type I, II, IV, V Grade 3 Class A, B, C; NSF/ANSI 61 |
Hole Conditions | Dry, water-saturated, and water-filled |
Packaging | 10 oz cartridge |
Is HYB-2CC approved for cracked concrete?
Yes. It is covered by ICC-ES ESR-4535 for cracked and uncracked concrete.
Can I install anchors in water-filled holes?
Yes. The adhesive is suitable for dry, water-saturated, and water-filled hole installations.
What service temperature limits apply?
The system is assessed for long-term loads up to 212°F with short-term exposure up to 320°F as part of AC308 and ACI 355.4 evaluations.
Is HYB-2CC acceptable for potable water applications?
Yes. It is certified to NSF/ANSI 61 for drinking water system components.
What mix ratio does the cartridge use?
The cartridge dispenses a 10:1 ratio by volume for consistent proportioning.
Brand | Adhesives Technology |
---|---|
Manufacturer | Adhesives Technology |
Please complete your information below to login.