Adhesives Technology HS-1CC Ultrabond 22oz A22-HS1CC

Ultrabond HS-1CC is a high performance epoxy anchoring system approved for use with threaded rod and reinforcing bar for cracked and uncracked concrete conditions, and internally threaded inserts in uncracked concrete.

  • Suitable for core drilled installations in dry or water saturated concrete
  • Multiple anchor types: threaded rod, rebar and internally threaded inserts
  • UL Certified
$36.21
Availability: In stock ( 100 Available )

Adhesives Technology ULTRABOND HS-1CC High-Strength Anchoring Epoxy, 22 oz Cartridge

ULTRABOND HS-1CC is a two-component, 1:1 epoxy anchoring adhesive for threaded rod and reinforcing bar in cracked or uncracked concrete, and for internally threaded inserts in uncracked concrete. It is approved for dry, water-saturated, water-filled, and submerged holes, including vertical, horizontal, and overhead placements. Working time is about 16 minutes at 75°F, with a 7-hour full cure. Also available as the ULTRABOND HS-1CC 9 oz and the ULTRABOND HS-1CC 53 oz.

Looking for another size?

Key Features

  • Anchors threaded rod and rebar in cracked or uncracked concrete
  • Approved for dry, water-saturated, water-filled, and submerged holes
  • Vertical down, horizontal, upwardly inclined, and overhead placements
  • Non-sag 1:1 epoxy that mixes gray
  • Code-range application from 43°F to 110°F
  • Suitable for core-drilled holes in dry or water-saturated concrete
  • NSF/ANSI 61 drinking water system components

Applications

  • Threaded rod in cracked or uncracked concrete
  • Reinforcing bar (rebar) doweling
  • Internally threaded inserts in uncracked concrete
  • Dry, damp, water-filled, and submerged installations
  • Transportation infrastructure work to AASHTO M235

Technical Specifications

Property Value
Chemistry Two-component epoxy, 1:1 by volume
Mixed color Gray
Consistency Non-sag
Compressive yield 14,480 psi at 7 days, 75°F (ASTM D695)
Heat deflection 148°F (64°C) (ASTM D648)
Working / full cure 16 min / 7 hr at 75°F
Application temperature 43 to 110°F (6 to 43°C)
ASTM C881-15 / AASHTO M235 Type I, II, IV and V, Grade 3, Class A, B and C
Evaluation IAPMO ER-591 (ACI 355.4 / ICC-ES AC308)
NSF NSF/ANSI 61 and 372
Shelf life 24 months (unopened, 40 to 95°F)
Packaging 21.2 fl oz (627 ml) cartridge, A22-HS1CC

Product documents: ULTRABOND HS-1CC Technical Data Sheet (PDF) | ULTRABOND HS-1CC Safety Data Sheet (PDF)

Frequently Asked Questions

Can Ultrabond HS-1CC be used in submerged underwater holes?
Yes. Ultrabond HS-1CC is approved for dry, water-saturated, water-filled, and submerged underwater conditions with threaded rod or rebar. Submerged holes are a HS-1CC listing. Do not copy that onto Ultrabond 1 or EPX-3CC.

Does Ultrabond HS-1CC cover core-drilled holes in uncracked concrete?
Yes. Ultrabond HS-1CC may be used in hammer-drilled cracked or uncracked concrete, and in core-drilled holes in uncracked concrete. Core-drill in uncracked concrete is a HS-1CC advantage on the current rev 5.3 sheet.

Can Ultrabond HS-1CC set internally threaded inserts?
Yes. Ultrabond HS-1CC is approved for internally threaded inserts in uncracked concrete, along with threaded rod and rebar in cracked or uncracked concrete. Multiple anchor types are part of the ESR-4094 listing.

Does Ultrabond HS-1CC carry NSF drinking-water and lead-free listings?
Ultrabond HS-1CC is UL certified to NSF/ANSI 61 for drinking-water system components and to NSF/ANSI 372 for lead-free content. That pair is why it is used on potable-water related anchoring as well as structural rod work.

What temperature windows does Ultrabond HS-1CC list for structural vs transportation work?
For IBC/IRC structural work, Ultrabond HS-1CC lists 43F to 110F. For transportation infrastructure to AASHTO M235 and ASTM C881-20, the sheet lists 38F to 125F. Use the window that matches the spec, and use the current rev 5.3 TDS, not the old C881-15 sheet.

When should a crew pick Ultrabond HS-1CC instead of Ultrabond HYB-2CC?
Pick Ultrabond HS-1CC when the job needs a high-strength 1:1 epoxy that covers cracked and uncracked concrete, submerged holes, and core-drilled uncracked holes. Pick Ultrabond HYB-2CC when the substrate is cold, down to 23F, or the crew needs a 30-minute full cure at 70F.