Ultrabond HS-1CC is a high performance epoxy anchoring system approved for use with threaded rod and reinforcing bar for cracked and uncracked concrete conditions, and internally threaded inserts in uncracked concrete.
ULTRABOND HS-1CC is a two-component, 1:1 epoxy anchoring adhesive for threaded rod and reinforcing bar in cracked or uncracked concrete, and for internally threaded inserts in uncracked concrete. It is approved for dry, water-saturated, water-filled, and submerged holes, including vertical, horizontal, and overhead placements. Working time is about 16 minutes at 75°F, with a 7-hour full cure. Also available as the ULTRABOND HS-1CC 9 oz and the ULTRABOND HS-1CC 53 oz.
| Property | Value |
|---|---|
| Chemistry | Two-component epoxy, 1:1 by volume |
| Mixed color | Gray |
| Consistency | Non-sag |
| Compressive yield | 14,480 psi at 7 days, 75°F (ASTM D695) |
| Heat deflection | 148°F (64°C) (ASTM D648) |
| Working / full cure | 16 min / 7 hr at 75°F |
| Application temperature | 43 to 110°F (6 to 43°C) |
| ASTM C881-15 / AASHTO M235 | Type I, II, IV and V, Grade 3, Class A, B and C |
| Evaluation | IAPMO ER-591 (ACI 355.4 / ICC-ES AC308) |
| NSF | NSF/ANSI 61 and 372 |
| Shelf life | 24 months (unopened, 40 to 95°F) |
| Packaging | 21.2 fl oz (627 ml) cartridge, A22-HS1CC |
Product documents: ULTRABOND HS-1CC Technical Data Sheet (PDF) | ULTRABOND HS-1CC Safety Data Sheet (PDF)
Can Ultrabond HS-1CC be used in submerged underwater holes?
Yes. Ultrabond HS-1CC is approved for dry, water-saturated, water-filled, and submerged underwater conditions with threaded rod or rebar. Submerged holes are a HS-1CC listing. Do not copy that onto Ultrabond 1 or EPX-3CC.
Does Ultrabond HS-1CC cover core-drilled holes in uncracked concrete?
Yes. Ultrabond HS-1CC may be used in hammer-drilled cracked or uncracked concrete, and in core-drilled holes in uncracked concrete. Core-drill in uncracked concrete is a HS-1CC advantage on the current rev 5.3 sheet.
Can Ultrabond HS-1CC set internally threaded inserts?
Yes. Ultrabond HS-1CC is approved for internally threaded inserts in uncracked concrete, along with threaded rod and rebar in cracked or uncracked concrete. Multiple anchor types are part of the ESR-4094 listing.
Does Ultrabond HS-1CC carry NSF drinking-water and lead-free listings?
Ultrabond HS-1CC is UL certified to NSF/ANSI 61 for drinking-water system components and to NSF/ANSI 372 for lead-free content. That pair is why it is used on potable-water related anchoring as well as structural rod work.
What temperature windows does Ultrabond HS-1CC list for structural vs transportation work?
For IBC/IRC structural work, Ultrabond HS-1CC lists 43F to 110F. For transportation infrastructure to AASHTO M235 and ASTM C881-20, the sheet lists 38F to 125F. Use the window that matches the spec, and use the current rev 5.3 TDS, not the old C881-15 sheet.
When should a crew pick Ultrabond HS-1CC instead of Ultrabond HYB-2CC?
Pick Ultrabond HS-1CC when the job needs a high-strength 1:1 epoxy that covers cracked and uncracked concrete, submerged holes, and core-drilled uncracked holes. Pick Ultrabond HYB-2CC when the substrate is cold, down to 23F, or the crew needs a 30-minute full cure at 70F.