ULTRABOND HS-1CC is a high-strength 1:1 epoxy anchoring adhesive for threaded rod and rebar in cracked or uncracked concrete.
ULTRABOND HS-1CC is a two-component, 1:1 epoxy anchoring adhesive for threaded rod and reinforcing bar in cracked or uncracked concrete, and for internally threaded inserts in uncracked concrete. It is approved for dry, water-saturated, water-filled, and submerged holes, including vertical, horizontal, and overhead placements. Working time is about 16 minutes at 75°F, with a 7-hour full cure. Also available as the ULTRABOND HS-1CC 22 oz and the ULTRABOND HS-1CC 53 oz.
| Property | Value |
|---|---|
| Chemistry | Two-component epoxy, 1:1 by volume |
| Mixed color | Gray |
| Consistency | Non-sag |
| Compressive yield | 14,480 psi at 7 days, 75°F (ASTM D695) |
| Heat deflection | 148°F (64°C) (ASTM D648) |
| Working / full cure | 16 min / 7 hr at 75°F |
| Application temperature | 43 to 110°F (6 to 43°C) |
| ASTM C881-15 / AASHTO M235 | Type I, II, IV and V, Grade 3, Class A, B and C |
| Evaluation | IAPMO ER-591 (ACI 355.4 / ICC-ES AC308) |
| NSF | NSF/ANSI 61 and 372 |
| Shelf life | 24 months (unopened, 40 to 95°F) |
| Packaging | 8.6 fl oz (254 ml) cartridge, A9-HS1CC, case of 12 |
Product documents: ULTRABOND HS-1CC Technical Data Sheet (PDF) | ULTRABOND HS-1CC Safety Data Sheet (PDF)
What is ULTRABOND HS-1CC?
ULTRABOND HS-1CC is a two-component, 1:1 epoxy anchoring adhesive for threaded rod and rebar in cracked or uncracked concrete, and for internally threaded inserts in uncracked concrete. This page is the 9 oz cartridge (A9-HS1CC), sold as a case of 12.
How do the cartridge sizes compare?
HS-1CC cartridges are the same published epoxy in three sizes. This page is the 9 oz cartridge (A9-HS1CC), case of 12. Other sizes: ULTRABOND HS-1CC 22 oz and ULTRABOND HS-1CC 53 oz.
Can HS-1CC be used in wet or submerged holes?
Yes. It is approved for dry, water-saturated, water-filled, and submerged conditions with threaded rod or rebar. Follow the manufacturer printed installation instructions for hole drilling and cleaning.
What is the working and full cure time?
At 75°F, working time is about 16 minutes and full cure is about 7 hours. At 43°F, working time is about 45 minutes and full cure is about 144 hours. Do not disturb, torque, or load the anchor until full cure.
Can HS-1CC be used overhead?
Yes. Vertical down, horizontal, upwardly inclined, and overhead placements are listed uses. Install per the datasheet and IAPMO ER-591.
How old must the concrete be before anchoring?
For anchoring applications, concrete should be a minimum of 21 days old prior to anchor installation per ACI 355.4.
Does HS-1CC meet ASTM C881?
Yes. The current TDS meets ASTM C881-15 and AASHTO M235 Type I, II, IV and V, Grade 3, Class A, B and C. It is evaluated to IAPMO ER-591 for cracked and uncracked concrete.