Leakmaster LV-Z is a single component water-swelling sealant with excellent and unique properties. The rubber-like elasticity of the material and expansion characteristics create an effective watertight seal.
Leakmaster LV-Z is a moisture-cure, one-component, water-swelling sealant used for waterproofing details where a continuous, gun-applied bead is needed. It swells approximately 2 times in volume through distilled water absorption and swelling mechanisms, helping provide water sealing performance without losing rubber-like elasticity.
| Property | Value |
|---|---|
| Product Type | One component type water-swelling sealant |
| Color | Gray |
| Appearance | Putty like |
| Extrudability | < 20 sec (In house test at 25°C) |
| Slump | < 10 mm (In house test for 1 hour test at 25°C) |
| Swelling Property | 85 to 200 vol.% (In house test after 2 days immersions at 25°C) |
| Shelf Life | 12 months after the production month and year shown on the cartridge |
| Storage | Store in a cool, dark and dry place below 90°F (32°C) |
| Use Temperature Range | 41°F (5°C) to 104°F (40°C) |
| Surface Condition | When the surface is wet, Leakmaster LV-Z is not suitable |
| Item | Value |
|---|---|
| Item No. | LV-Z |
| Contents | 320 ml per cartridge |
| Unit | 24 cartridges per carton |
Where is Leakmaster LV-Z commonly used?
Main applications include water sealing at vertical joints of cast in-situ concrete, precast concrete, and general waterproofing work. It can also be used as an adhesive to the first site formed concrete before CJ installation when the surface is rough.
How does Leakmaster LV-Z help seal against water?
It is a water-swelling sealant that swells approximately 2 times in volume as a result of distilled water absorption and swelling mechanisms, supporting water sealing without losing rubber-like elasticity.
Can Leakmaster LV-Z be applied when the surface is wet?
No. When the surface is wet, Leakmaster LV-Z is not suitable.
What is the recommended use temperature range?
Use at a temperature between 41°F (5°C) and 104°F (40°C).
What are the storage and shelf life requirements?
Store in a cool, dark and dry place below 90°F (32°C). Use within its shelf life of 12 months after the production month and year shown on the cartridge.
Are there placement requirements for cast in-situ concrete joints?
Keep a minimum of 100 mm concrete coverage on both sides of the Leakmaster LV-Z position when used for site formed concrete joints.
What are the basic application steps for the cartridge?
Break the moisture-proofing aluminum foil on the top of the cartridge, cut the nozzle at the appropriate position, set the cartridge to a caulking gun, and apply continuously without a break to the place to be sealed.