Euclid Hi-Flow Metallic Grout is a high-flow, metallic aggregate grout designed for precision grouting and anchoring applications. It offers exceptional flowability and high bond strength, making it ideal for demanding anchoring projects.
Hi-Flow Metallic Grout is a high tolerance, non-shrink cementitious grout formulated with a metallic aggregate system and a shrinkage-compensating binder. It is designed for critical grouting where high fluidity and high strength are required, including heavy-duty machinery and equipment, structural columns, crane rails, bridge seats, and bearing plates.
| Property | Value |
|---|---|
| Packaging | 50 lb (22.7 kg) bags |
| Approximate Yield | 0.40 ft³ (0.011 m³) per 50 lb unit when mixed with 1.2 gal (4.6 L) potable water |
| Shelf Life | 9 months in original, unopened package |
| Specifications and Compliances | CRD-C 621; ASTM C1107; shows positive expansion when tested to ASTM C1090 |
| Flow Rate (ASTM C939 / CRD-C 621) | Initial: 22 seconds; 30 minutes: 45 seconds; 60 minutes: 51 seconds |
| Compressive Strength (ASTM C109M, 2 in cubes) | 1 day: 4,000 psi (27 MPa); 3 days: 6,000 psi (40 MPa); 7 days: 7,000 psi (47 MPa); 28 days: 9,000 psi (61 MPa) |
| Volume Change (ASTM C1090 / CRD-C 621) | +0.03% at 1, 3, 7, and 28 days |
| Split Tensile Strength (ASTM C496) | 550 psi (3.7 MPa) at 28 days |
| Setting Time (ASTM C191) | Initial set: 3 hrs 50 mins; Final set: 4 hrs 50 mins |
What is Hi-Flow Metallic Grout used for?
It is used for high tolerance, high strength grouting where high fluidity is required, including heavy-duty machinery and equipment, structural columns, crane rails, bridge seats, and bearing plates.
What standards does it meet?
It complies with CRD-C 621 and ASTM C1107 and shows positive expansion when tested in accordance with ASTM C1090.
How much mixing water is used per 50 lb bag?
Fluid: 1.0 to 1.2 gal (3.8 to 4.5 L); Flowable: 0.9 to 1.0 gal (3.4 to 3.8 L); Plastic: 0.8 to 0.9 gal (3.0 to 3.4 L). Mix time is 5 minutes.
When is pea gravel required?
When placed at thicknesses over 5 in (12.7 cm), add up to 20 lb (9.1 kg) of pea gravel per bag. Water demand may change based on the target flow.
What placement temperatures are recommended?
It is designed to be fluid poured from 40 to 100°F (4 to 38°C) and is most easily placed at 60 to 70°F (16 to 21°C).
Please complete your information below to login.