Euclid EucoRepair V100 is a single-component, quick-setting, low-shrinkage mortar for vertical and overhead concrete repair. Polymer-modified and fiber-reinforced, it includes an integral corrosion inhibitor for parking structures, bridges, tanks, and marine work.
Euclid EucoRepair V100 is a single-component, quick-setting, low-shrinkage repair mortar formulated with polymers and fiber reinforcement for vertical and overhead work. It is used on parking structures, bridges, water and wastewater treatment facilities, marine structures, tunnels, and dams, above and below grade. The mortar has an integral corrosion inhibitor, freeze-thaw resistance, and NSF/ANSI/CAN 61 certification for potable water.
| Property | Value |
|---|---|
| 3-hour compressive | 2,000 psi |
| 1-day compressive | 3,000 psi |
| 28-day compressive | 6,000 psi |
| 28-day bond | >1,800 psi |
| 28-day flexural | >600 psi |
| Length change, 28 days | -0.020% |
| Initial set | 20 minutes |
| Working time | about 10 to 15 minutes at 72 F |
| Application thickness | vertical 1/8 to 4 in; overhead 1/8 to 2 in per lift |
| Yield | 0.45 ft³ per 46 lb |
EucoRepair V100 Technical Data Sheet
What vertical work is Euclid EucoRepair V100 used for?
Euclid EucoRepair V100 is used for vertical and overhead repairs on parking structures, bridges, water and wastewater treatment facilities, marine structures, tunnels, and dams. It is used above and below grade.
When does Euclid EucoRepair V100 take initial set?
Approximate initial set is 20 minutes. Approximate final set is 35 minutes. Typical laboratory values. Expect reasonable variation under field conditions.
What 3-hour compressive strength does Euclid EucoRepair V100 reach?
Typical laboratory value is 2,000 psi at 3 hours on 2 inch cubes (ASTM C109M). 1-day compressive strength is 3,000 psi; 28-day is 6,000 psi. Expect reasonable variation under field conditions.
What thickness does Euclid EucoRepair V100 cover per lift?
Vertical placement is 1/8 to 4 inches per lift. Overhead placement is 1/8 to 2 inches per lift. Minimum thickness is 1/8 inch on both orientations.
What listing covers Euclid EucoRepair V100 in potable-water vessels?
Euclid EucoRepair V100 is NSF/ANSI/CAN 61 certified for use with potable water. That listing is on the current EucoRepair V100 data sheet.
When is Euclid EucoRepair V100 ready for a coating?
Euclid EucoRepair V100 is ready for a coating after 6 hours at 70 F. Typical laboratory value. Expect reasonable variation under field conditions.
Please complete your information below to login.