Euclid Euco 700 is a 100% solids semi-rigid epoxy joint filler in a 2 gallon unit. It is placed in industrial concrete control and construction joints to support joint edges under wheel traffic.
Euclid Euco 700 is a two-component, 100% solids semi-rigid epoxy joint filler. It is used in concrete construction and control joints, crack filling in older floors, and interior industrial and commercial slabs. The formula supports joint edges under wheel traffic, follows ACI 302 recommendations for epoxy joint fillers, and is placed above 40 F, with a complete cure within one week.
| Property | Value |
|---|---|
| Mix ratio, A:B | 1:1 by volume |
| Pot life, 75 F | 15 minutes |
| Tack-free, 75 F | 12 hours |
| Compressive strength, ASTM D695 | 3,000 psi |
| Tensile strength, ASTM D638 | 690 psi |
| Elongation, 7 days, ASTM D638 | 55% |
| Shore hardness, ASTM D2240 | Shore D 55 at 7 days; Shore A > 100 |
| Water absorption, ASTM D570 | 1.1% (72 hour) |
| Traffic ready | 24 hours at 70 F and 50% RH |
| Yield, 1 gallon | 231 in³ |
Where is Euclid Euco 700 used?
Euclid Euco 700 is used in concrete construction and control joints, crack filling in older floors, and interior industrial and commercial slabs. It supports joint edges and reduces spalling from wheel traffic.
What pot life does Euclid Euco 700 have at 75 F?
Typical laboratory pot life is 15 minutes at 75 F. Tack-free time is 12 hours at 75 F. Expect reasonable variation under field conditions.
How soon is Euclid Euco 700 ready for traffic?
Typical laboratory traffic-ready time is 24 hours at 70 F and 50% relative humidity. Complete cure is within one week. Lower temperatures slow the curing rate. Expect reasonable variation under field conditions.
What compressive strength does Euclid Euco 700 show?
Typical laboratory compressive strength is 3,000 psi (ASTM D695). Tensile strength is 690 psi (ASTM D638). Expect reasonable variation under field conditions.
What Shore D hardness does Euclid Euco 700 show?
Typical laboratory Shore D hardness is 55 at 7 days (ASTM D2240). Shore A hardness is greater than 100. Expect reasonable variation under field conditions.
How soon can Euclid Euco 700 be applied after the slab is placed?
ACI 302 recommends installing joint fillers as late as possible after construction so additional slab shrinkage is limited. Euclid Euco 700 is placed only at temperatures above 40 F.
Please complete your information below to login.