Euclid Dural LPL MV is a two-component, 100% solids, moisture-insensitive, high-modulus epoxy bonding agent in a 1 gal unit. Medium viscosity with extended working time for bonding fresh plastic concrete to existing concrete and steel.
Euclid Dural LPL MV is a two-component, 100% solids, high-modulus epoxy adhesive and binder. It is used to bond fresh plastic concrete to existing concrete and steel, to anchor bolts, dowels, or pins, and as a general adhesive for concrete and masonry. Combined with dried silica sand it becomes a repair mortar. Working time stays open longer than conventional epoxy bonding agents.
| Property | Value |
|---|---|
| ASTM C881 | Type II, Grade 2, Class C |
| Mixed viscosity, 60 F | 3,700 cp |
| Gel time, 60 F | 105 minutes |
| Gel time, 90 F | 60 minutes |
| Bond strength, 14 days, 50 ft²/gal, 60 F | 2,120 psi |
| Compressive yield, 7 days, 60 F | 10,570 psi |
| Tensile strength, 7 days | 7,400 psi |
| Water absorption, 24 hours | 0.2% |
| Open time, fresh-to-hardened | 5 to 6 hours at 75 F |
| Application temperature | 60 to 90 F |
Dural LPL MV Technical Data Sheet
Where is Euclid Dural LPL MV used?
Euclid Dural LPL MV is used to bond fresh plastic concrete to existing concrete and steel, to anchor bolts, dowels, or pins, and as a general adhesive for concrete and masonry. Combined with dried silica sand it becomes a repair mortar.
How long does Euclid Dural LPL MV stay open on fresh-to-hardened work?
Open time is typically 5 to 6 hours at 75 F. Warmer temperatures reduce that window. Do not place concrete over dried epoxy.
What gel time does Euclid Dural LPL MV show at 60 F?
Typical laboratory gel time is 105 minutes at 60 F (ASTM C881). Gel time is 60 minutes at 90 F. Expect reasonable variation under field conditions.
What 14-day bond strength does Euclid Dural LPL MV show?
Typical laboratory bond strength at 14 days is 2,120 psi at 50 ft²/gal and 60 F (ASTM C882). At 100 ft²/gal and 60 F it is 2,060 psi. Expect reasonable variation under field conditions.
What ASTM C881 listing does Euclid Dural LPL MV have?
Euclid Dural LPL MV is listed as ASTM C881 Type II, Grade 2, Class C. It is also listed to AASHTO M 235.
What application temperature does Euclid Dural LPL MV need?
Surface and ambient temperature should be 60 F to 90 F. Material temperature should be at least 60 F and rising.
Please complete your information below to login.