Euclid EUCO QWIKjoint 200 is a fast-setting, semi-rigid polyurea joint filler for control and construction joints in industrial concrete floors. It supports joint edges under heavy wheel traffic.
Euclid EUCO QWIKjoint 200 is a fast-setting, semi-rigid polyurea joint filler. It is used in concrete construction and control joints, crack repair on older floors, and industrial and commercial slabs, including freezer floors. The formula is less moisture-sensitive than standard polyureas, does not foam in damp joints, and reduces joint-edge spalling under heavy loads.
| Property | Value |
|---|---|
| Gel time | 25 seconds |
| Tack-free time | 1 to 3 minutes |
| Traffic ready | Light 15 min; heavy 30 min |
| Shore A, ASTM D2240 | 84 to 88 |
| Shore D, ASTM D2240 | 34 to 36 |
| Tensile strength, 7 days, ASTM D412 | 660 psi |
| Elongation, 7 days, ASTM D412 | 220% to 260% |
| Application temperature | -20 F to 90 F |
| Yield, 1 gal | 231 in³ |
| Shelf life | 1 year unopened |
EUCO QWIKjoint 200 Technical Data Sheet
Where is Euclid EUCO QWIKjoint 200 used?
Euclid EUCO QWIKjoint 200 is used in concrete construction and control joints, crack repair on older floors, and industrial and commercial floors, including freezer floors. It supports and protects joint edges from heavy loads and wheel traffic.
What gel time does Euclid EUCO QWIKjoint 200 show?
Typical laboratory gel time is 25 seconds. Tack-free time is 1 to 3 minutes. Expect reasonable variation under field conditions.
How soon is Euclid EUCO QWIKjoint 200 ready for traffic?
Typical laboratory traffic-ready time is 15 minutes for light traffic and 30 minutes for heavy traffic. Expect reasonable variation under field conditions.
What application temperature does Euclid EUCO QWIKjoint 200 need?
Surface and ambient temperature should be between -20 F and 90 F. Keep material and application equipment at 50 F or above.
What Shore A hardness does Euclid EUCO QWIKjoint 200 show?
Typical laboratory Shore A hardness is 84 to 88 (ASTM D2240). Shore D hardness is 34 to 36. Expect reasonable variation under field conditions.
What 7-day tensile strength does Euclid EUCO QWIKjoint 200 show?
Typical laboratory tensile strength is 660 psi at 7 days (ASTM D412). Elongation at 7 days is 220% to 260%. Expect reasonable variation under field conditions.