Euclid E3 Xtreme is a versatile, high-performance epoxy mortar and grout offering exceptional strength and durability. It excels in applications requiring reliable bonding and long-lasting performance.
E3-Xtreme is a three-component, ultra-high performance epoxy grout engineered for dynamic load applications. With DL Technology™ aggregate to reduce dust during handling, E3-Xtreme delivers ultra-high compressive strength, very low creep, and >95% Effective Bearing Area (EBA). It is highly chemical resistant, has excellent tensile and flexural strength, and provides long-term stability under rotating equipment, presses, turbines, and heavy industrial machinery.
Compressive Strength (ASTM C579) | 15,800 psi (1 day); 17,000 psi (7 days); 17,500 psi (28 days); 19,000 psi (post cure) |
Flexural Strength (ASTM C580) | 5,500 psi (1 day); 5,600 psi (7 days); 5,650 psi (28 days); 5,700 psi (post cure) |
Tensile Strength (ASTM C307) | 1,900 psi (1 day); 2,000 psi (7 days); 2,300 psi (28 days); 2,400 psi (post cure) |
Bond Strength (ASTM C882) | 3,300 psi (7 days); 3,900 psi (28 days) |
Effective Bearing Area (ASTM C1339) | Greater than 95% |
Working Time (ICRI Protocol) | Approx. 32 minutes at 73°F (23°C) |
Coefficient of Thermal Expansion (ASTM C531) | 2.2 x 10⁻⁵ in/in/°F (74 to 210°F) |
Peak Exotherm (ASTM D2471) | 168°F at 65 minutes (12 in x 12 in x 3 in specimen) |
Chemical Resistance | Excellent resistance to most industrial chemicals |
Abrasion Resistance | Greater than concrete |
Packaging | 1.7 CF kit (1 pail + 6 bags) |
What sets E3-Xtreme apart from other epoxy grouts?
Its ultra-high compressive strength, very low creep, and DL Technology™ aggregate make it ideal for heavy dynamic load applications.
Can E3-Xtreme resist chemicals?
Yes. It is highly resistant to most industrial chemicals and offers superior abrasion resistance compared to concrete.
What is the Effective Bearing Area (EBA)?
Greater than 95%, ensuring stable load transfer under heavy equipment.
How long is the working time?
Approximately 32 minutes at 73°F (23°C).
How do I clean tools after mixing?
Tools and mixers can be cleaned with soap and water before the grout hardens.
Brand | Euclid Chemical |
---|---|
Manufacturer | Euclid Chemical |