Parcel Orders over $300 Ship Free.
Euclid Diamond Clear 5 Gallon Pail 359 05

Euclid Diamond Clear 5 Gallon Pail 359 05

Euclid Aqua-Cure VOX 5 Gallon Pail 050V 05

Euclid Aqua-Cure VOX 5 Gallon Pail

Euclid Diamond Clear 350 5 Gallon Pail 359DC 05

Euclid Diamond Clear 350 is an exempt-solvent acrylic curing compound and cure and seal in a 5 gallon pail. It is used on fresh exterior concrete.

  • Medium-gloss film that darkens concrete
  • Will not yellow under ultraviolet exposure
  • Holds moisture so strength and durability can develop
$257.23
Drop Shipped

Euclid Diamond Clear 350 Acrylic Cure and Seal, 5 gallon pail

Euclid Diamond Clear 350 is an exempt-solvent acrylic curing compound and cure and seal. It is used on fresh exterior concrete, including walls, columns, parking garages, and dry-shake floors. It holds moisture so strength and durability can develop, and the film is non-yellowing under ultraviolet exposure. Air and surface temperature should be between 40 F and 85 F.

Key Features

  • Exempt-solvent acrylic cure and seal
  • Non-yellowing under ultraviolet exposure
  • Medium-gloss film that darkens concrete
  • Holds moisture so strength and durability can develop
  • Complies with VOC standards in the OTC and LADCO states
  • ASTM C309 Type 1, Classes A and B

Applications

  • Curing and sealing fresh concrete surfaces.
  • Walls and columns.
  • Parking garages.
  • Dry-shake hardened floors.

Technical Specifications

Property Value
VOC 320 g/L
Solids content 12 to 13%
Dry to touch < 1 hour at 70 F
Recoat minimum 2 hours
Foot traffic 2 to 4 hours
Wheel traffic 6 to 10 hours
Coverage 400 to 450 ft²/gal
ASTM C309 Type 1, Classes A and B
AASHTO M 148 Type 1, Classes A and B
Application temperature 40 F to 85 F

Documents

Diamond Clear 350 Technical Data Sheet

Frequently Asked Questions

Where is Euclid Diamond Clear 350 used?
Fresh exterior concrete, including walls, columns, parking garages, and dry-shake hardened floors.

What is the solids content of Euclid Diamond Clear 350?
Typical laboratory solids content is 12 to 13%.

What is the recoat time of Euclid Diamond Clear 350?
Typical laboratory recoat time is a minimum of 2 hours at 70 F. Expect reasonable variation under field conditions.

What is the ASTM C309 listing of Euclid Diamond Clear 350?
ASTM C309 Type 1, Classes A and B. It also meets AASHTO M 148 Type 1, Classes A and B.

How soon is Euclid Diamond Clear 350 ready for foot traffic?
Typical laboratory foot traffic is 2 to 4 hours. Wheel traffic is 6 to 10 hours at 70 F. Expect reasonable variation under field conditions.

What application temperature does Euclid Diamond Clear 350 need?
Air and surface temperature should be between 40 F and 85 F.