Emseal Backerseal is a precompressed secondary foam seal for 1/8 to 6 inch joints behind liquid sealant on facades, masonry, and EIFS. It expands against the joint faces, backing up the primary seal if that seal is punctured.
Emseal Backerseal is a Greyflex precompressed acrylic-impregnated polyurethane foam used as a watertight secondary seal behind liquid sealant in wall joints. It is used on precast, brick, stone, metal, masonry control joints, EIFS, and as a mullion baffle. It is placed from reels or shrink-wrapped sticks, depending on width. Color is charcoal grey.
| Property | Value |
|---|---|
| Movement | +25% / -25% (50% total) |
| Pack, ≤5/8 in | 13.12 LF (4 m) reels |
| Pack, ≤1 in | 6.56 LF (2 m) reels |
| Pack, >1 in | 6.56 LF (2 m) sticks |
| Color | Charcoal Grey |
| Temperature | -40 F to 185 F |
| Thermal conductivity | 0.34 Btu·in/hr·ft²·°F, ASTM C518 |
| Water penetration | ASTM E331 passed to 20.88 PSF |
| Wind gust | ASTM E330 +62.66 / -56.39 PSF |
| Substrate backpressure | about 2.5 psi |
What role does Backerseal play behind a liquid sealant?
It provides watertight secondary sealing in two ways: behind a conventionally installed liquid sealant and backer rod, or behind a directly field-applied low-modulus liquid sealant. When it is used with a directly applied liquid sealant, the two technologies form a binary sealant system whose performance exceeds that of the individual components. The acrylic impregnation is compatible with all major wet sealants and will not contaminate the substrate at the wet-sealant bond area, and the foam provides an economical backup seal if the primary liquid sealant is punctured or fails.
What joint sizes and supply forms does Backerseal cover?
It is available for joint-gap sizes from 1/8 inch (3 mm) to 6 inches (150 mm), selected to match the joint gap at mean temperature; custom sizes and depths are available from Sika Emseal. Material up to 5/8 inch (15 mm) is supplied on 13.12 LF (4 m) reels, up to 1 inch (25 mm) on 6.56 LF (2 m) reels, and over 1 inch in 6.56 LF (2 m) shrink-wrapped sticks. Seal depth is 5/8 inch at the 1/8 inch size and grows with width to 6 inches of depth at the 6 inch size.
What movement and weather testing can a Backerseal wall joint expect?
It is rated for joint movement of +25% and -25% of nominal material width, or 50% total. Under curtain-wall testing it passed ASTM E283 for air leakage, ASTM E331 for water penetration up to 20.88 psf, and ASTM E330 for gust loading at +62.66 and -56.39 psf. Permanent service range is -40°F to 185°F under ASTM C711, and Xenon arc weathering showed no visible deterioration after 2000 hours.
What substrates and wall systems can Backerseal serve?
It can be used in vertical and horizontal joints in building facades of precast concrete, brick, natural stone, metal, and most other substrates, and it backs up liquid sealants in masonry control joints. It is also suited to panelized cladding, window-wall systems, skylights, and precast panels that rely on the barrier-wall sealing principle. As a baffle in vertical mullions of curtainwall systems, it can mitigate moisture intrusion and the noisy movement of air known as the stack effect.
What makes the foam a fit for EIFS joints?
The Backerseal binary-sealant system is suited to new and retrofit joints in Exterior Insulation and Finish Systems because the Greyflex water-based, stabilized acrylic impregnation is 100% compatible with EIFS substrates and its backpressure places minimal tension on a potentially weak substrate. The depth and resiliency of the foam reduce the effects of air-pressure differential, the binary sealant principle eliminates the moisture-trap area commonly created between wet sealants and backer rods, and the foam thermally insulates the EIFS cladding at the joints.
What conditions keep Backerseal from being the right choice?
It is designed for use in vertical surfaces such as walls and facades, and it is not intended for use in the horizontal plane such as floors or decks. It will not adhere to joints that are dirty or dust-covered, or to surfaces coated with oils or release agents, and it is not resistant to sustained contact with petroleum solvents, oils, selected waxes, active chlorine, heavy oxidized acids, or strong lyes. Substrate faces must be parallel, have enough clear depth to fully support the foam and the liquid sealant, and resist about 2.5 psi of backpressure without deflection.