Euclid Tamms Structural Mortar is a single-component, polymer- and fiber-modified portland cement mortar for structural concrete repair. Spray at low pressure or trowel. About 30 minutes working time; 3/8 to 2 inches per lift.
Euclid Tamms Structural Mortar is a single-component repair mortar of portland cement, graded aggregates, micro fibers, silica fume, and polymers. It is used on vertical and overhead structural concrete, interior or exterior, including potable-water and wastewater structures. The mortar is freeze-thaw resistant, carries an integral corrosion inhibitor, and is compatible with galvanic anodes.
| Property | Value |
|---|---|
| 1-day compressive | 3,200 psi |
| 7-day compressive | 6,200 psi |
| 28-day compressive | 8,500 psi |
| 28-day flexural | 1,650 psi |
| 28-day shear bond | 3,250 psi |
| Initial set | 1 hour |
| Application thickness | 3/8 to 2 in per lift |
| Application temperature | 40 F and rising |
| Freeze/thaw, 300 cycles | 96% RDF |
| Yield | 0.45 ft³ per 50 lb |
Tamms Structural Mortar Technical Data Sheet
Where is Euclid Tamms Structural Mortar used?
Euclid Tamms Structural Mortar is used on vertical and overhead concrete repairs, interior and exterior. Primary applications are bridges, parking garages, tunnels, manholes, pipelines, dams, and wastewater structures.
What potable-water listing does Euclid Tamms Structural Mortar have?
It is NSF/ANSI Standard 61 certified for use with potable water. It is used on potable-water and wastewater structures, including manholes, pipelines, and dams.
What working time does Euclid Tamms Structural Mortar have?
Working time is 30 minutes. Typical laboratory value. Expect reasonable variation under field conditions.
What lift thickness does Euclid Tamms Structural Mortar have?
Application thickness is 3/8 to 2 inches per lift.
What galvanic anode compatibility does Euclid Tamms Structural Mortar have?
It is compatible with galvanic anodes on structural repairs, including bridges, parking garages, and tunnels.
What freeze-thaw result does Euclid Tamms Structural Mortar show?
Freeze/thaw resistance is 96% RDF after 300 cycles (ASTM C666). Typical laboratory value. Expect reasonable variation under field conditions.