Euclid Dural Fast Set LV is a two-component, 100% solids, moisture-insensitive, rapid-setting epoxy adhesive and binder. This high-modulus, low-viscosity resin is for general bonding and for injecting cracks in concrete.
Euclid Dural Fast Set LV is a rapid-setting, high-modulus, low-viscosity epoxy adhesive and binder. It is used to bond concrete, masonry, or wood, as an injection resin for cracked structural substrates, and to gravity-feed cracks in concrete slabs. Combined with dried silica sand it becomes a repair mortar. The resin is placed as low as 40 F and rising.
| Property | Value |
|---|---|
| Mixed viscosity | 800 cp |
| Gel time | 6 minutes |
| Bond strength, 2 days | 2,300 psi |
| Bond strength, 14 days | 2,600 psi |
| Water absorption, 24 hours | 0.1% |
| Heat deflection temperature | 135 F |
| Compressive yield, 2 hours | 10,500 psi |
| Compressive yield, 7 days | 15,500 psi |
| Tensile strength, 7 days | 10,000 psi |
| Application temperature | 40 to 90 F |
Dural Fast Set LV Technical Data Sheet
When is Euclid Dural Fast Set LV held off a leaking crack?
Injection of Euclid Dural Fast Set LV is held if water is leaking from the crack. The rapid-setting, low-viscosity resin is the injection material for cracked, structural substrates.
What mixed viscosity does Euclid Dural Fast Set LV show?
Typical laboratory mixed viscosity is 800 cp (ASTM D2556). The high-modulus, low-viscosity resin is used so it can penetrate deep into cracks. Expect reasonable variation under field conditions.
What 2-hour compressive yield does Euclid Dural Fast Set LV show?
Typical laboratory compressive yield is 10,500 psi at 2 hours (ASTM D695). One-hour compressive yield is 4,000 psi. Four-hour compressive yield is 13,000 psi. Expect reasonable variation under field conditions.
What 24-hour water absorption does Euclid Dural Fast Set LV show?
Typical laboratory water absorption is 0.1% at 24 hours (ASTM D570). Expect reasonable variation under field conditions.
What 7-day compressive modulus does Euclid Dural Fast Set LV show?
Typical laboratory compressive modulus is 575,000 psi at 7 days (ASTM D695). Expect reasonable variation under field conditions.
What elongation at break does Euclid Dural Fast Set LV show?
Typical laboratory elongation at break is 1.9% (ASTM D638). Expect reasonable variation under field conditions.