Nano-Lithium hardener, densifier and hydrophobic sealer ideal for protecting concrete and masonry surfaces against damage from freeze-thaw cycles, moisture, and chloride ion intrusion.
Pentra-Sil 244+ is a premium Nano-Lithium hardener, densifier, and hydrophobic sealer for concrete and masonry. It combines lithium densification with reactive silicone chemistry to meet NCHRP 244 chloride protection in a single application. The treatment penetrates to reduce permeability, harden and dust-proof the surface, and help prevent efflorescence and spalling while remaining breathable and UV stable. Do not use as a time-of-placement densifier; wait at least seven days after placement before application.
| Packaging (this item) | 5 gal pail (18.93 L). Also available: 1 gal, 55 gal drum, 275 gal tote. |
| Appearance | Liquid with red tint; dries clear. |
| Total Solids / VOC | 17.1% solids; VOC < 50 g/L. |
| pH / Specific Gravity | pH 11–12; specific gravity 1.10. |
| Estimated Coverage | Machine-troweled: 600–800 ft²/gal; broom-finished: 250–350 ft²/gal (substrate dependent). |
| Application Conditions | Apply when temperatures will remain above 40°F for at least 2 hours after application; keep surface wet with product for ~20 minutes. |
| Use Timing | Not a time-of-placement densifier; wait minimum 7 days after placement to avoid white staining. |
| Clean Up | Soap and water. Product is alkaline; follow SDS guidance. |
| Certifications | UL 2818 Greenguard Gold low-emissions. |
| Performance Notes | Abrasion resistance +30.4% (ASTM C779); water absorption improvement 8.4% (ASTM C642, Type I) and 5.9% (Type IL). |
| Shelf Life / Freeze Point | 1 year unopened; freeze point 32°F. |
How soon after placing concrete can I apply 244+?
Wait at least seven days after placement. Early application can cause white staining on new concrete.
Do I need to rinse after application?
No rinse is needed on most surfaces. On machine-troweled, dyed, acid-stained, or integrally colored concrete, scrub with water after 20–30 minutes and pick up excess material.
What surface prep is required?
Remove dirt, laitance, curing compounds, or coatings that block penetration. Avoid acidic or citrus cleaners; neutralize any residues with an alkaline cleaner.
Is it breathable and UV stable?
Yes. The treatment is breathable and not susceptible to UV damage.
How do I estimate coverage?
Plan for 600–800 ft²/gal on machine-troweled concrete and 250–350 ft²/gal on broom-finished surfaces; porosity and conditions affect actual rate.