Parcel Orders over $300 Ship Free.
Air Sentry D-103 Breather

Air Sentry D-103 Breather

Five Star Rapid Epoxy Grout 32500

Five Star Rapid Epoxy Grout 32500

Air Sentry X-102 Desiccant Breather

X-Series Breathers are the perfect solution for high humidity and high dust environments. To extend the desiccant’s life, the X-Series incorporates two check valves and a reusable top cap. The check valves provide a closed system until airflow is required, extending the service life of the desiccant.

  • High humidity applications
  • High dust applications
  • Uses check valves to extend lifespan
$230.25
Drop Shipped
SKU
14323

Air Sentry X-102 Desiccant Breather

Air Sentry X-102 is a high humidity and high dust desiccant breather used to reduce moisture and particulate contamination in reservoirs and storage tanks that breathe during level and temperature changes. The X-Series design uses check valves and a reusable top cap to keep the system closed until airflow is required, extending desiccant service life. When the silica gel changes from gold to dark green, replace the desiccant cartridge and reuse the top cap.

Key Features

  • Designed for high humidity and high dust environments.
  • Check valves help keep the system closed until airflow is required.
  • Reusable top cap supports fast cartridge changes.
  • Two 2-micron filters, one on the inlet and one on the outlet.
  • Color-changing silica gel indicates when the cartridge is spent.
  • Operating temperature: -20°F (-29°C) to +200°F (+93°C).

Applications

  • Hydraulic reservoirs and lubrication reservoirs.
  • Storage tanks and bulk oil systems.
  • Gearboxes and enclosed systems that breathe to atmosphere.
  • High humidity and high dust environments such as wash-down areas, paper mills, steam-cleaning rooms, and mine quarries.

Technical Specifications:

Property Value
Model X-102 (095X102)
Dimensions 10 in x 5 in
Mounting Connection 1 inch slip fit
Type of Medium 100% silica gel
Silica Gel 2.7 lbs (1.2 kg)
Maximum Adsorption Capacity 16.56 fl oz (489 mL)
Maximum Air Flow 20 cfm
Maximum Reservoir Fluid Flow 150 gpm
Filtration 2-micron filters on inlet and outlet
Replacement Cartridge A-342
Operating Temperature -20°F (-29°C) to +200°F (+93°C)

Frequently Asked Questions

What is the X-102 used for?
It is a desiccant breather used on breathing reservoirs and tanks to help reduce moisture and particulate contamination that can shorten fluid life.

How do the check valves help?
The X-Series uses check valves to keep the system closed until airflow is required. Airflow into the breather occurs when differential pressure exceeds the intake threshold, and air exits the reservoir when the exhaust threshold is exceeded.

How do I know when the cartridge needs to be replaced?
When the silica gel changes from gold to dark green, replace the desiccant cartridge.

How is the cartridge replaced?
Remove the reusable top cap from the spent cartridge, dispose of the cartridge, and install the same top cap on the replacement cartridge.

What connection and size does the X-102 use?
The X-102 uses a 1 inch slip fit connection and is listed as 10 inches by 5 inches.